Signal direction
Count forward and reverse signals, including clocks, data, enable and return paths. For SPI, review the complete interface and timing budget.
No products in the cart.
Find the right signal path.
Build a precise sourcing request.
Compare channel direction, supply rails, isolation ratings and integrated power. Review manufacturer datasheets, then send your exact part numbers or BOM to ApexComponent.
Signal isolation and power isolation are separate selections.
Signal flow illustration. Refer to the selected device's pinout and power requirements.
Count signals in both directions. F means A → B; R means B → A.
Opposing unidirectional channels are different from the open-drain bidirectional channels used by I²C.
Current products from our Digital Isolators catalog. Compare listed specifications and request a quote by exact part number.
Filter options follow the current catalog. Missing specifications are marked See product; review the exact ordering code and datasheet.
Current product catalog
Scroll table ↓ / ↔ · F / R = forward / reverse| Product / manufacturer | Direction | Supply | Isolation withstand | Rate | Power | Package | Details / RFQ |
|---|
Reset one or more filters, or send the required MPN and specifications for review.
Products sync when this page opens and every minute while it is visible. VISO is a short-duration withstand test, not the continuous working voltage. Price, availability and lead time are confirmed on inquiry.
Open a product page to review the listed part number and prepare an inquiry.
Use these four steps before approving a part or an alternative.
Count forward and reverse signals, including clocks, data, enable and return paths. For SPI, review the complete interface and timing budget.
Match working voltage, insulation type, surge requirements, creepage and clearance to the system. Review the exact package's safety documentation.
Check each side's supply and input thresholds, maximum propagation delay, skew and CMTI. Keep typical and guaranteed limits separate.
Choose an external isolated supply or a part with an integrated isolated DC-DC converter. Check output load, startup, thermal limits and EMI.
Each side has its own supply. Internal regulators on a device do not necessarily transfer energy across the barrier.
Power crosses the barrier through the integrated converter. Specify the input / output voltage combination and available load.
Compare integrated-power references ↗Manufacturer references: TI digital isolator design guide ↗ · Analog Devices safety documentation ↗
Choose the signal function before comparing channel count.
Use the required channel directions and logic rails. Check clock / data delay, skew and startup states against your circuit.
ADUM1250ARZ provides two bidirectional channels. Review pull-ups, VOL, bus capacitance, clock stretching and the maximum I²C clock.
ADUM3160WBRWZ-RL supports low and full speed at 1.5 / 12 Mbps. Review speed configuration, enumeration and power on each side.
CAN and RS-485 bus drivers, isolated gate drivers and analog isolation devices serve different signal functions. Specify the interface in your inquiry.
Keep the complete manufacturer ordering code in your BOM and RFQ.
ADUM1201ARZ-RL7 is a 1 Mbps A-grade part. The same family contains faster grades with different timing limits.
ISO7741DWR and the F-suffix variant have different default output behavior. DW and DBQ packages have different isolation and physical dimensions.
Compare pinout, direction, supply, timing, output state, package and insulation evidence. Include engineering-approved alternatives in the request.
Practical answers for selection and purchasing.
It transfers digital information between electrically separated circuit domains. A general-purpose digital isolator carries logic signals; protocol-specific isolators add the circuitry needed for interfaces such as I²C or USB.
It means three signals travel from Side 1 to Side 2, and one travels in the reverse direction. These are four unidirectional channels. They are different from a single channel that automatically supports bidirectional, open-drain communication.
No. The VISO figure in this table is a short-duration withstand rating. Review VIOWM / VIORM, insulation classification, surge ratings, package spacing and the applicable system requirements separately.
No. Most general-purpose signal isolators require power on both sides. ISOW7741DFMR and ADUM5401ARWZ include an isolated DC-DC converter; their usable load depends on operating conditions. Internal LDO regulators alone are not an isolated power converter.
Do not select only by channel count. I²C requires the appropriate open-drain direction handling and logic thresholds. USB has protocol and speed requirements. Choose a device or circuit explicitly suited to the required interface.
Review electrical interface, pin assignment, supply, timing, startup / default output, package and insulation requirements. A similar function or footprint does not establish interchangeability. Send the original full MPN and approved replacement requirements.
Add reference parts to a list, set quantities and include the conditions your design needs.
Copy your list into the inquiry form, or upload the downloaded TXT with your BOM. Submit the request on the inquiry page.
No parts added yet. Choose a product above, or send your own MPN.
Add a part and enter its quantity to prepare your list.
Availability, price, lead time, traceability and replacement approval are confirmed for the specific sourcing request.
WhatsApp us