On a powered TJA1057 in Silent mode, RXD still carries the bus bitstream even though the node cannot acknowledge a frame. Put a TJA1043 into Standby and the same probe tells you about wake requests. In Sleep, its INH pin can also determine whether the rest of the board has power. Start with the fitted part number.
Cover. Photo by Liz Clark / Adafruit, CC BY-SA 3.0 (resized).

TJA1057 Silent Mode vs. TJA1043 Standby and Sleep
The table below compares documented operating modes from the NXP TJA1057 data sheet (Rev. 8.1) and NXP TJA1043 data sheet (Rev. 7.0).
| Mode (Device & Ref.) | Control Pins | TX / Normal RX | RXD Output | INH & Bus Bias |
|---|---|---|---|---|
| Silent (TJA1057, Sec. 7.1.2) | S = HIGH | TX off / RX active | Live bus frame bits | No INH; bus biased to recessive |
| Listen-only (TJA1043, Sec. 7.2.2) | STB_N = HIGH, EN = LOW | TX off / RX active | Live bus frame bits | INH active HIGH; bus at 0.5 VCC |
| Standby (TJA1043, Sec. 7.2.3) | STB_N = LOW, EN = LOW | TX off / Normal RX off (wake RX on) | Wake-up indication (with ERR_N) | INH active HIGH; bus biased to GND |
| Sleep (TJA1043, Sec. 7.2.4–7.2.5) | Go-to-Sleep (STB_N = LOW, EN = HIGH) held > th(min) | TX off / Normal RX off (wake RX on) | Wake-up indication (if VIO & VBAT valid) | INH floating (external regulator can shut down); bus to GND |

Hardware Modes vs. Controller Listen-Only, ACK, and Qualified Wake
- Controller listen-only vs. hardware Silent/Listen-only: MCU controller listen-only mode mutes transmission inside the protocol engine without changing the hardware mode. If the transceiver remains in Normal, budget for its Normal-mode current. Hardware Silent (TJA1057) or Listen-only (TJA1043) disables the physical driver. In either case, the node cannot transmit a dominant ACK bit—so a two-node bench setup will trigger sender ACK errors unless another active node acknowledges frames.
RXDwake indication vs. frame data: In TJA1057 Silent mode,RXDmirrors every dominant and recessive bit on the bus. In TJA1043 Standby and Sleep modes, normal reception stops;RXD(alongsideERR_N) signals a latched wake-up request wheneverVIOandVBATare present, not decoded CAN payloads (TJA1043 Sec. 7.2.3, 7.3).- Qualified wake vs. individual bits: Remote wake requires dominant, recessive and dominant phases of sufficient duration within the specified timeout. A local WAKE transition must remain stable for the specified filter time. Power-on also sets the Wake flag (TJA1043 sections 7.3.4–7.3.5).

Troubleshooting Sequence
- Verify mode pins and Go-to-Sleep timing: On TJA1057, confirm
Sis HIGH for Silent mode. On TJA1043, confirmSTB_N= LOW andEN= HIGH are held without interruption for longer than the minimum hold timeth(min)with the Wake flag cleared; any pin change or pending Wake flag aborts Sleep entry (Sec. 7.2.4, Table 5).
Use the schematic for the exact board revision to identify its fitted transceiver and available mode controls. Photo by Liz Clark / Adafruit, CC BY-SA 3.0 (resized). - Check
INHand regulator state: If the node never powers down in TJA1043 Sleep mode, probeINH. It stays HIGH in Standby and floats only in Sleep; verify external pull-down resistance and regulator enable thresholds (Sec. 7.2.5). - Clear latched wake flags before re-testing Sleep: On TJA1043, a set Wake flag forces Standby instead of Sleep when
STB_Nis LOW. Transition to Normal mode to clear the Wake flag before issuing Go-to-Sleep (Sec. 7.2, 7.3). - Measure current per supply rail and pin condition: Separate
VCC,VIO, andVBATmeasurements. On TJA1057, hold bothTXDandSHIGH in Silent mode to eliminate internal pull-up current (Sec. 7.2.2). On TJA1043, rememberVBATpowers the wake-up receiver and internal logic (Sec. 7.1); verifyIBATagainst the datasheet static characteristics under your exactVBAT,WAKE, andINHconditions rather than judging standby draw fromICCandIIOalone.
A board can have several supply paths. Include the regulator and MCU when measuring standby current. Photo by Kattni Rembor / Adafruit, CC BY-SA 3.0 (resized). - Confirm bus ACK coverage: If the bus logs ACK errors during Silent or Listen-only diagnostics, ensure a receiver other than the sender has an active controller and transceiver, matching bit timing, and can acknowledge a valid frame.
Next Steps for CAN Transceiver Selection and Sourcing
If your troubleshooting shows that your node only needs transmitter muting without regulator shutdown, read our TJA1051 vs. TJA1057 selection guide to verify pinout and VIO requirements. If your power budget requires Standby/Sleep modes, INH regulator control, or qualified bus wake-up, browse ApexComponent CAN transceiver ICs to compare wake-capable families. Once your candidate part is defined, submit your request via ApexComponent Send Inquiry with the full MPN, quantity, wake-up requirements, and standby current budget.