ISO7721 and ISO6721 should be compared as complete ordering codes, not as interchangeable family names. The first screening differences are speed, supported supplies, package options, and isolation requirements. A candidate can pass one of those checks and still fail another.
This guide uses ISO7721DR and ISO6721BDR, two catalog-grade, narrow SOIC-8 examples, to make the comparison concrete. It also shows why an extra R in an ISO6721 ordering code deserves attention. Use the comparison to prepare an engineering shortlist and a precise quote request; replacement approval requires the conditions of the actual circuit.
Start with two exact candidates
The following values apply to the named candidates and the datasheet revisions cited below.
| Screening item | ISO7721DR | ISO6721BDR |
|---|---|---|
| Maximum data rate | 100 Mbps | 50 Mbps |
| Recommended supply ranges, each side | 2.25–5.5 V | 1.71–1.89 V or 2.25–5.5 V |
| Ambient operating temperature | −55 to +125 °C | −40 to +125 °C |
| Package | D, 8-pin narrow SOIC | D, 8-pin narrow SOIC |
| Selected default output option | High | High |
Sources: ISO772x datasheet, Rev. G, Sections 6.3 and 8.3 and ISO672x datasheet, Rev. F, Sections 6.3 and 8.3. A default output applies only under the device’s specified conditions, with the receiving side able to operate.
Before comparing prices, write down the existing full code and the proposed full code. Attach the same requirement sheet to both. That prevents a supplier response from silently changing package width, default logic, or operating grade while preserving a familiar family name.

Check the signal pins before assuming a drop-in change
For the D-package examples above, the supply, ground, and signal pin assignments match. ISO6721RBDR changes the signal directions at the corresponding signal pins. The extra R within the device name matters; it is different from the terminal R used for reel ordering.
The original diagram below groups the matching pair and contrasts the reverse-pinout variant. It is a top-view functional reference, not a land-pattern drawing. Check the footprint, lead dimensions, and pin-one orientation separately.

These assignments were checked against ISO772x Figure 5-4 and Table 5-1 and ISO672x Figures 5-2/5-3 and Table 5-1.
On an existing schematic, trace each driver to an isolator input and each receiver to an output. Repeat that check for both directions. Treat a reversed direction as a circuit change that needs review, even if the replacement fits the pads.
A useful change record therefore has two separate fields: “pin-function comparison completed” and “application replacement approved.” The first is evidence for the second, not a substitute for it.
Treat the supply specification as a window
A nominal rail label is not a full voltage requirement. Include regulator tolerance, load variation, ripple, and any interval during which valid communication is required. The minimum and maximum voltage must remain within a supported operating window.
The ISO672x recommended-operating table explicitly separates its low-voltage window from its higher-voltage window. Its footnote identifies the intervening region as one in which outputs are undetermined. Do not merge the two ranges in a purchasing specification. See Section 6.3 and footnote 3.

A tolerance example you can reuse
Suppose a proposed nominal 1.8 V rail has a symmetric ±5% tolerance:
Vmin = 1.8 × (1 − 0.05) = 1.71 V
Vmax = 1.8 × (1 + 0.05) = 1.89 V
That assumed tolerance uses the entire low-voltage window. It leaves no additional voltage allowance for effects not already included in the ±5% specification. With an assumed ±10% tolerance, the endpoints become 1.62 V and 1.98 V, so the rail no longer stays inside that window.
This is an arithmetic example, not a measured supply. Budget the actual rail error at the IC pins and decide which conditions are already included. Otherwise, adding “another” ripple allowance may either double-count an existing limit or reveal a missing one.
Also check logic thresholds against the devices driving and receiving each channel. TI explains the distinction between independent supplies and local signal levels in its digital-isolator design questions. A supported supply does not, by itself, complete the interface-level check.
Match isolation ratings to the package and application
The ISO772x family headline includes a 5000 VRMS withstand rating for DW and DWV packages; the D package is rated at 3000 VRMS. ISO6721BDR is also a 3000 VRMS D-package device. These are withstand values with specified test conditions, including a 60-second qualification test, not a continuous operating-voltage recommendation. See the respective ISO772x and ISO672x insulation tables.
Equal withstand numbers do not settle an insulation substitution. Review working voltage, surge, spacing, and the required insulation class together. The reviewed ISO672xB document covers basic insulation. For an ISO7721 option, use the package-specific certification entry under the applicable equipment standard; do not turn the family-level “reinforced” description into a universal application approval.
TI’s Digital Isolator Design Guide, Section 3 provides the selection framework. For an engineering handoff, record the standard and required insulation class, the relevant package row, the working-voltage requirement, and the board-spacing review. Leaving one of those fields blank is more useful than filling it with a guessed pass.
Keep signal immunity as a separate check. The companion CMTI guide explains why a withstand rating cannot answer whether fast ground movement will disturb the signal.
Compare timing at the same conditions
Both families list an 11 ns typical propagation delay at 3.3 V, despite their different maximum data rates. Under each datasheet’s 3.3 V ±10% switching conditions, the maximum delay is 18.5 ns for ISO772x and 18 ns for ISO672x; maximum pulse-width distortion is 5.9 ns and 7 ns, respectively. Check the associated measurement setup and load: ISO772x Section 6.16 and ISO672x Section 6.18.
Those rows illustrate why a speed headline is insufficient. A timing review needs maximum delay, pulse distortion, and the receiver’s sampling requirement. Equal typical delays do not make the parts timing-equivalent.

For a clocked interface, draw the clock and data paths from launch to sampling. Include each isolator crossing, the remote device’s response time, routing, and receiver setup time. Use the correct worst-case values for the supplies and temperature range.
For example, assume a simplified transaction budget of 50 ns and an allocated 20 ns maximum delay for each of two isolation crossings. The remaining budget would be:
50 ns − 20 ns − 20 ns = 10 ns
That 10 ns must accommodate all remaining delays and margin. These are assumed budget inputs, not specifications for either candidate. The correct sampling interval depends on the protocol, clock phase, and implementation; the equation does not establish a supported SPI frequency.
If the existing design operates close to a limit, the substitution review should identify the limiting path before purchasing a trial lot. A slower nominal interface rate alone does not prove every pulse and startup condition is acceptable.
Keep the default state and ordering code in the BOM
High-default examples in this article are ISO7721DR and ISO6721BDR. The corresponding low-default D-package examples are ISO7721FDR and ISO6721FBDR. Confirm the full selected code in TI’s ordering information instead of adding or removing characters by analogy.
Default behavior needs its own acceptance statement. Write down what the receiving circuit must do when the source side loses power and what must happen when power returns. For that review, use the companion default-output and power-loss guide alongside the candidate’s function table.
Do not translate “default low” into “safe” without the receiver’s logic definition. A low input may disable one circuit and activate another. Also distinguish missing input-side power from missing receiving-side power.

Use the following fields in an RFQ or replacement request:
| Field | What to provide |
|---|---|
| Device identity | Existing and proposed complete MPN; manufacturer; required operating grade |
| Mechanical fit | Package drawing, footprint revision, pin-one view, and pin-function check |
| Electrical operation | Both rail ranges, logic levels, output load, and temperature range |
| Signal timing | Interface, rate, sampling relationship, and available timing margin |
| Isolation requirement | Applicable standard, insulation class, working/transient requirements, and spacing constraints |
| Power behavior | Required inactive command, default option, and startup/shutdown acceptance criteria |
| Commercial request | Quantity, packaging preference, target delivery date, and whether alternatives may be proposed |
The official ordering pages for ISO7721DR, ISO6721BDR, and ISO6721RBDR provide a reference for the exact identities discussed here. Check current ordering and qualification information at the time of purchase.
Browse the digital isolator category to develop a shortlist. For a quotation, send the complete MPN, quantity, and the requirement fields above through ApexComponent’s inquiry form. Availability, price, delivery, and any proposed alternative require confirmation for that request.
Frequently asked questions
Can ISO6721 replace ISO7721 directly?
Do not approve it from the family names. Compare the exact package and pinout, supply windows, insulation requirements, timing limits, default state, and grade. Matching pin functions completes only one part of the review.
Does the R in ISO6721RBDR only mean reel packaging?
No. The R immediately after ISO6721 identifies the reverse-pinout device variant. The final R is part of the packaging suffix. Keep the complete manufacturer code when requesting or approving parts.
Which part is cheaper?
This document does not establish a current price difference. Compare quotations for the exact approved codes, quantity, packaging, and delivery conditions. An engineering change can also introduce review and validation work that a unit-price comparison misses.
Sources and review method
Prepared on 18 November 2026 using TI’s ISO772x datasheet SLLSEP3G, revised May 2024, ISO672x datasheet SLLSFJ0F, revised February 2023, current ordering pages, and the linked design guidance. Pin diagrams and specification-table columns were checked against the original PDF pages.
This is a document-based comparison with explicitly assumed calculations. No bench testing, end-equipment qualification, or supply availability is claimed. The scope is the catalog devices named here; automotive −Q1 and other variants require their own documents.